dc.description.abstractThe article deals with the stress-strain analysis of human mandible in the physiological state and after the dental implant application. The evaluation is focused on assessing of the cancellous bone tissue modeling-level. Three cancellous bone model-types are assessed: Non-trabecular model with homogenous isotropic material, nontrabecular model with inhomogeneous material obtained from computer tomography data using CT Data Analysis software, and trabecular model built from mandible section image. Computational modeling was chosen as the most suitable solution method and the solution on two-dimensional level was carried out. The results show that strain is more preferable value than stress in case of evaluation of mechanical response in cancellous bone. The non-trabecular model with CT-obtained material model is not acceptable for stress-strain analysis of the cancellous bone for singularities occurring on interfaces of regions with different values of modulus of elasticity.en
dc.format14 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUniversity of West Bohemiaen
dc.relation.ispartofseriesApplied and Computational Mechanicsen
dc.rights© 2011 University of West Bohemia. All rights reserved.en
dc.subjectzubní implantátcs
dc.subjecttrabekulární kostics
dc.subjectmetoda konečných prvkůcs
dc.subjectpevnostní analýzacs
dc.subjectdeformační analýzacs
dc.subjectmodelovací úroveňcs
dc.titleBiomechanical study of the bone tissue with dental implants interactionen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.subject.translateddental implanten
dc.subject.translatedtrabecular bonesen
dc.subject.translatedfinite element methoden
dc.subject.translatedstress analysisen
dc.subject.translatedstrain analysisen
dc.subject.translatedmodelling levelen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Volume 5, number 2 (2011)
Volume 5, number 2 (2011)

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
125.pdf934,46 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/1341

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.