Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Tkáč, Ján | |
dc.contributor.author | Dolník, Bystrik | |
dc.contributor.author | Kurimský, Juraj | |
dc.contributor.author | Vilček, Miroslav | |
dc.contributor.editor | Mühlbacher, Jan | |
dc.date.accessioned | 2017-02-22T07:26:38Z | |
dc.date.available | 2017-02-22T07:26:38Z | |
dc.date.issued | 2006 | |
dc.identifier.citation | Proceedings of the Intensive Programme 2006. 1st ed. Pilsen: University of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineering, 2006, s. 60-64. ISBN 80-7043-456-2. | en |
dc.identifier.isbn | 80-7043-456-2 | |
dc.identifier.uri | http://home.zcu.cz/~tesarova/IP/Proceedings/Proc_2006/index.htm | |
dc.identifier.uri | http://hdl.handle.net/11025/25336 | |
dc.format | 5 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | University of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineering | en |
dc.rights | © University of West Bohemia | en |
dc.subject | akustický hluk | cs |
dc.subject | výboj | cs |
dc.subject | akustický senzor | cs |
dc.title | Acoustic detection of noise emission from discharge activity in power engineering | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | This article deals with results from analysis of acoustic signal obtained from experiments realized in nonhomogeneous electric field. These signals exist in the form unwanted noise which can be used also for diagnostic purpose. In power engineering this case occure in high voltage power station and transmission lines. We analyse acoustic signal from acoustic sensor in audible band from 1 kHz to 20 kHz. The acoustic signal transmitted from object is unique for specific conditions. Exploitation of audible band for discharge detection is difficult in outdoor bias level. Advantage of this method consist in simple results prepare. | en |
dc.subject.translated | acoustic noise | en |
dc.subject.translated | discharge | en |
dc.subject.translated | acoustic sensore | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Proceedings of the intensive programme 2006 Proceedings of the intensive programme 2006 |
Soubory připojené k záznamu: