Full metadata record
DC FieldValueLanguage
dc.contributor.authorMühlbacher, Jan
dc.contributor.authorNechanický, M.
dc.contributor.authorNovák, P.
dc.contributor.authorHeřman, A.
dc.contributor.editorMühlbacher, Jan
dc.date.accessioned2017-02-22T08:13:26Z
dc.date.available2017-02-22T08:13:26Z
dc.date.issued2006
dc.identifier.citationProceedings of the Intensive Programme 2006. 1st ed. Pilsen: University of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineering, 2006, s. 3-8. ISBN 80-7043-456-2.en
dc.identifier.isbn80-7043-456-2
dc.identifier.urihttp://home.zcu.cz/~tesarova/IP/Proceedings/Proc_2006/index.htm
dc.identifier.urihttp://hdl.handle.net/11025/25346
dc.format6 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUniversity of West Bohemia. Faculty of electrical engineering. Department of electrical power engineering and environmental engineeringen
dc.rights© University of West Bohemiaen
dc.subjectobnovitelné zdroje energiecs
dc.subjectalternativní zdroje energiecs
dc.subjectelektrárnycs
dc.subjectzdrojecs
dc.subjectnapětícs
dc.subjectvětrná energetikacs
dc.titleImpacts of renewable and alternative energy sources on operation and stability of electrical networken
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThis paper deals with the evaluation of renewable and alternative energy sources network interconnection and their impacts on the operation and stability of electrical network. The article shows the dependence of the voltage level magnitude in the point of common connection on the power factor of the renewable energy sources generator. The following part analyses, how the short-term power variation of the power plants (wind and photovoltaic) regarding the weather changes cause the voltage variations according to the generator operational mode. These variations negatively influence the distribution network operation and the power quality. The dynamic variations were simulated by the NEPLAN software. In conclusion the feasibility of the plant interconnection is evaluated respecting other important factors (flicker, ripple control signal damping, harmonic voltages content, protective relays function).en
dc.subject.translatedrenewable energy sourcesen
dc.subject.translatedalternative energy sourcesen
dc.subject.translatedpower plantsen
dc.subject.translatedsourcesen
dc.subject.translatedvoltageen
dc.subject.translatedwind energyen
dc.type.statusPeer-revieweden
Appears in Collections:Proceedings of the intensive programme 2006
Články / Articles (KEE)
Proceedings of the intensive programme 2006

Files in This Item:
File Description SizeFormat 
Muhlbacher.pdfPlný text147,61 kBAdobe PDFView/Open


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/25346

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.