dc.identifier.citationNOVÁK, M., MATAS, R., SEDLÁČEK, J. Numerical simulations of flue gas flow in a first stage filter with top inlet - Modifications of the inlet chamber inserts. In 36th Meeting of Departments of Fluid Mechanics and Thermodynamics. MELVILLE, NY 11747-4501 US: AIP Conference Proceedings, 2017. s. nestránkováno. ISBN: 978-0-7354-1572-0 , ISSN: 0094-243Xen
dc.identifier.isbn978-0-7354-1572-0
dc.identifier.issn0094-243X
dc.identifier.uri2-s2.0-85030778875
dc.identifier.urihttp://hdl.handle.net/11025/29498
dc.identifier.urihttps://aip.scitation.org/journal/apc
dc.description.abstractČlánek je zaměřen na simulaci toku spalin v prvním stupni filtru s horním přívodem, který se používá v kogenerační elektrárně. Simulace CFD byla provedena s důrazem na vliv vstupní komory na rovnoměrnou distribuci spalin. Proud se musí otáčet ve správném směru v poměrně malém prostoru. K dosažení této změny se ve vstupní komoře používají rozdělovací stěny s klapkami a vložkami. Výsledky ukázaly, že hlavní vliv na rozložení rychlosti uvnitř filtru maji vložky v komoře.cs
dc.format9 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherAIP Conference Proceedingsen
dc.relation.ispartofseries36th Meeting of Departments of Fluid Mechanics and Thermodynamicsen
dc.rightsPlný text není přístupný.cs
dc.rights© AIP Conference Proceedingsen
dc.subjectElektrostatický filtrcs
dc.subjectnumerická simulace proudění, homogenizace prouděnSGS-2016-045cs
dc.titleNumerické simulace průtoku spalin v prvním stupni filtru s horním přívodem - modifikace vstupních komorových vložekcs
dc.titleNumerical simulations of flue gas flow in a first stage filter with top inlet - Modifications of the inlet chamber insertsen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe paper is focused on flue gas flow simulations in a first stage filter with top inlet that is used in a cogeneration power plant. CFD simulations were done with emphasize on the influence of inlet chamber on the flue gas distribution and filtering process. The flow has to be turned at right direction in a quite small space. To achieve this change, distribution walls with flaps and duct inserts are used in the inlet chamber. The results showed that the main influence on the velocity distribution inside the filter have the inserts in the chamberen
dc.subject.translatedElectrostatic filteren
dc.subject.translatedCFD simulationen
dc.subject.translatedflow homogenizationen
dc.identifier.doi10.1063/1.5004360
dc.type.statusPeer-revieweden
dc.identifier.document-number417391000026
dc.identifier.obd43921606
dc.project.IDSGS-2016-045/Zvyšování účinnosti, spolehlivosti a životnosti energetických strojů a zařízení 4cs
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (MIS)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
1.5004360_Matas.pdf2,4 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/29498

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD