Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorMazúr, Petr
dc.contributor.authorMrlík, J.
dc.contributor.authorBeneš, Jan
dc.contributor.authorPocedič, Jaromír
dc.contributor.authorVrána, Jiří
dc.contributor.authorDundálek, Jan
dc.contributor.authorKosek, Juraj
dc.date.accessioned2018-06-21T10:00:15Z-
dc.date.available2018-06-21T10:00:15Z-
dc.date.issued2018
dc.identifier.citationMAZÚR, P., MRLÍK, J., BENEŠ, J., POCEDIČ, J., VRÁNA, J., DUNDÁLEK, J., KOSEK, J. Performance evaluation of thermally treated graphite felt electrodes for vanadium redox flow battery and their four-point single cell characterization. Journal of power sources, 2018, roč. 380, č. MAR 15 2018, s. 105-114. ISSN 0378-7753.en
dc.identifier.issn0378-7753
dc.identifier.uri2-s2.0-85041736009
dc.identifier.urihttp://hdl.handle.net/11025/29794
dc.description.abstractV našem příspěvku studujeme elektrokatalytický efekt kyslíkových funkčních skupin tepelně upravené grafitové plsti na kinetiku elektrodových reakcí vanadové redoxní průtočné baterie. Chemické a morfologické změny plstí jsou analyzovány standardními fyzikálně chemickými metodami. Pro charakterizaci plstí v laboratorním monočlánku byla vyvinuta komplexní metoda čtyřbodového měření. Metoda je založena na elektrochemické impedanční spektroskopii a měření zátěžových křivek kladných a záporných poločlánků pomocí vložených pseudo-referenčních elektrod z platinového drátku. Distribuce ohmických a faradaických ztrát v monočlánku byla vyhodnocena jak pro symetrickou, tak pro asymetrickou konfiguraci elektrod s ohledem na podmínky úpravy. Pozitivní vliv funkcionalizace plstí je pozorován pouze u záporné elektrody, zatímco kinetika kladné elektrodové reakce je téměř neovlivněna úpravou. To je v rozporu s výsledky typicky používané cyklovoltametrické charakterizace, které naznačují, že obě elektrody jsou aktivovány úpravou v podobném rozsahu. Vyvinutá čtyřbodová charakterizační metodika může být dále využita např. k optimalizaci vnitřních komponent bateriového článku, či pro in-situ studium životnosti redoxních průtočných baterií na bázi různých chemií.cs
dc.format10 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherElsevieren
dc.rightsPlný text není přístupný.cs
dc.rights© Elsevieren
dc.subjectVanadová redoxní průtočná bateriecs
dc.subjectGrafitová plstcs
dc.subjectFunkcionalizace kyslíkemcs
dc.subjectElektrochemická impedanční spektroskopiecs
dc.subjectZátěžová křivkacs
dc.subjectCyklická voltametriecs
dc.titleVyhodnocení výkonnosti tepelně upravených grafitových plstěných elektrod pro vanadovou redoxní průtočnou baterii a jejich čtyřbodová charakterizace v monočlánkucs
dc.titlePerformance evaluation of thermally treated graphite felt electrodes for vanadium redox flow battery and their four-point single cell characterizationen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedIn our contribution we study the electrocatalytic effect of oxygen functionalization of thermally treated graphite felt on kinetics of electrode reactions of vanadium redox flow battery. Chemical and morphological changes of the felts are analysed by standard physico-chemical characterization techniques. A complex method four-point method is developed and employed for characterization of the felts in a laboratory single-cell. The method is based on electrochemical impedance spectroscopy and load curves measurements of positive and negative half-cells using platinum wire pseudoreference electrodes. The distribution of ohmic and faradaic losses within a single-cell is evaluated for both symmetric and asymmetric electrode set-up with respect to the treatment conditions. Positive effect of oxygen functionalization is observed only for negative electrode, whereas kinetics of positive electrode reaction is almost unaffected by the treatment. This is in a contradiction to the results of typically employed cyclovoltammetric characterization which indicate that both electrodes are enhanced by the treatment to a similar extent. The developed four-point characterization method can be further used e.g., for the component screening and in-situ durability studies on singlecell scale redox flow batteries of various chemistries.en
dc.subject.translatedPerformance evaluation of thermally treated graphite felt electrodes for vanadium redox flow battery and their four-point single cell characterizationen
dc.identifier.doi10.1016/j.jpowsour.2018.01.079
dc.type.statusPeer-revieweden
dc.identifier.document-number428007400012
dc.identifier.obd43922178
dc.project.IDGP14-33400P/Studium kinetiky elektrodových reakcí na uhlíkových elektrodách s ohledem na fukcionalizaci a morfologii povrchu elektrodcs
Vyskytuje se v kolekcích:Články / Articles (CTM)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
1-s2.0-S037877531830079X-main.pdf1,01 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/29794

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD