Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorJansová, M.
dc.contributor.authorMalotín, T.
dc.contributor.authorKřen, J.
dc.contributor.authorVotápek, P.
dc.contributor.authorLobovský, L.
dc.contributor.authorHynčík, L.
dc.contributor.editorAdámek, Vítězslav
dc.contributor.editorJonášová, Alena
dc.contributor.editorPlánička, Stanislav
dc.contributor.editorZajíček, Martin
dc.date.accessioned2019-01-16T08:16:15Z-
dc.date.available2019-01-16T08:16:15Z-
dc.date.issued2018
dc.identifier.citationComputational mechanics 2018: book of extended abstracts: 34th conference with international participation, p. 33-34.en
dc.identifier.isbn978-80-261-0819-1
dc.identifier.urihttp://hdl.handle.net/11025/30794
dc.identifier.urihttps://www.zcu.cz/export/sites/zcu/pracoviste/vyd/online/FAV_Computational_Mechanics_2018.pdf
dc.description.sponsorshipThe work was supported from European Regional Development Fund-Project Application of Modern Technologies in Medicine and Industry (No. CZ.02.1.01/0.0/0.0/17_048/0007280) and by projects SGS-2016-012 and SGS-2016-059 of the University of West Bohemia.en
dc.format2 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherZápadočeská univerzita v Plznics
dc.relation.ispartofseriesComputational Mechanicsen
dc.rightsCopyright © 2018 University of West Bohemia, Plzeň, Czech Republicen
dc.subjectmodel zlomené kostics
dc.subjectcelková artroplastika kolenacs
dc.subjectbiomechanické testovánícs
dc.titleA comparative analysis of treatment of a supracondylar periprosthetic femoral fracture under axial load and torqueen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedA total knee arthroplasty (TKA) is in rare cases followed by an extra-articular fracture of distal femur. One type of fracture is a simple extra-articular fracture (A1 according to Schewring and Meggitt). It can be stabilized only by surgical treatment. Several implant types are used by orthopedic surgeons for its management. In this study we compare a response to axial load and torque for Distal Femoral Nail (DFN) and Locking Compression Plate (LCP). The model of bone with fracture, TKA and DFN is the same one as in the previous study. Both compact and spongy bone are modelled by 3D elements. The gap of partially healed fracture with a callus is 2 mm wide. LCP geometry is based on a laser scan. The finite element models with the placement of DFN and LCP are shown in Fig. 1. The material parameters of bone were obtained from available literature, the callus which forms several weeks after the fracture has material properties of a cartilage. The screws, the spiral blade, DFN and LCP are made of titanium alloy.en
dc.subject.translatedmodel of bone with fractureen
dc.subject.translatedtotal knee arthroplastyen
dc.subject.translatedbiomechanical testingen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Články / Articles (MMI)
Konferenční příspěvky / Conference Papers (KME)
Konferenční příspěvky / Conference papers (NTIS)
Computational mechanics 2018
Computational mechanics 2018

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
Jansova.pdfPlný text280,82 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/30794

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.