Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Jansová, M. | |
dc.contributor.author | Malotín, T. | |
dc.contributor.author | Křen, J. | |
dc.contributor.author | Votápek, P. | |
dc.contributor.author | Lobovský, L. | |
dc.contributor.author | Hynčík, L. | |
dc.contributor.editor | Adámek, Vítězslav | |
dc.contributor.editor | Jonášová, Alena | |
dc.contributor.editor | Plánička, Stanislav | |
dc.contributor.editor | Zajíček, Martin | |
dc.date.accessioned | 2019-01-16T08:16:15Z | - |
dc.date.available | 2019-01-16T08:16:15Z | - |
dc.date.issued | 2018 | |
dc.identifier.citation | Computational mechanics 2018: book of extended abstracts: 34th conference with international participation, p. 33-34. | en |
dc.identifier.isbn | 978-80-261-0819-1 | |
dc.identifier.uri | http://hdl.handle.net/11025/30794 | |
dc.identifier.uri | https://www.zcu.cz/export/sites/zcu/pracoviste/vyd/online/FAV_Computational_Mechanics_2018.pdf | |
dc.description.sponsorship | The work was supported from European Regional Development Fund-Project Application of Modern Technologies in Medicine and Industry (No. CZ.02.1.01/0.0/0.0/17_048/0007280) and by projects SGS-2016-012 and SGS-2016-059 of the University of West Bohemia. | en |
dc.format | 2 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | Západočeská univerzita v Plzni | cs |
dc.relation.ispartofseries | Computational Mechanics | en |
dc.rights | Copyright © 2018 University of West Bohemia, Plzeň, Czech Republic | en |
dc.subject | model zlomené kosti | cs |
dc.subject | celková artroplastika kolena | cs |
dc.subject | biomechanické testování | cs |
dc.title | A comparative analysis of treatment of a supracondylar periprosthetic femoral fracture under axial load and torque | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | A total knee arthroplasty (TKA) is in rare cases followed by an extra-articular fracture of distal femur. One type of fracture is a simple extra-articular fracture (A1 according to Schewring and Meggitt). It can be stabilized only by surgical treatment. Several implant types are used by orthopedic surgeons for its management. In this study we compare a response to axial load and torque for Distal Femoral Nail (DFN) and Locking Compression Plate (LCP). The model of bone with fracture, TKA and DFN is the same one as in the previous study. Both compact and spongy bone are modelled by 3D elements. The gap of partially healed fracture with a callus is 2 mm wide. LCP geometry is based on a laser scan. The finite element models with the placement of DFN and LCP are shown in Fig. 1. The material parameters of bone were obtained from available literature, the callus which forms several weeks after the fracture has material properties of a cartilage. The screws, the spiral blade, DFN and LCP are made of titanium alloy. | en |
dc.subject.translated | model of bone with fracture | en |
dc.subject.translated | total knee arthroplasty | en |
dc.subject.translated | biomechanical testing | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Články / Articles (MMI) Konferenční příspěvky / Conference Papers (KME) Konferenční příspěvky / Conference papers (NTIS) Computational mechanics 2018 Computational mechanics 2018 |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Jansova.pdf | Plný text | 280,82 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/30794
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.