Title: | Monitoring of a skin temperature in vicinity of a surgical wound |
Authors: | Tolar, David Štork, Milan |
Citation: | 2016 International Conference on Applied Electronics: Pilsen, 6th – 7th September 2016, Czech Republic, p.273-276. |
Issue Date: | 2016 |
Publisher: | Západočeská univerzita v Plzni |
Document type: | konferenční příspěvek conferenceObject |
URI: | http://hdl.handle.net/11025/35297 |
ISBN: | 978–80–261–0601–2 (Print) 978–80–261–0602–9 (Online) |
ISSN: | 1803–7232 (Print) 1805–9597 (Online) |
Keywords: | měření teploty;teplotní senzory;kůže;monitoring;zranění;bezdrátová komunikace |
Keywords in different language: | temperature measurement;temperature sensors;skin;monitoring;wounds;wireless communication |
Abstract in different language: | This article describes experimental measurements of a skin temperature in vicinity of a surgical wound. Measurements were carried out in collaboration with the orthopedic department of the University Hospital Olomouc, Czech Republic. A system used for sensing, transmission and visualization of physiological parameters was developed at the University of West Bohemia in Pilsen. A main goal of measurements was to evaluate technical parameters of the system, and also non-technical aspects associated with the use of the system. Technical parameters that was verified was a reliability of the system as a whole. This covers a temperature and motion sensing, a wireless transfer of measured data from sensors through wireless routers to the data server and data visualization in web application. To asses non-technical aspects of the system use, a sociological survey was carried out. Patients were asked to answer several questions related to the use of the system and temperature sensors. Conducted series of measurements and the survey showed that the vast majority of patients are accepting new technology positively. Measurements also verified the usability of the temperature sensor for local skin temperature measurement. Furthermore measurements revealed some issues associated with use of the sensor for monitoring of human body temperature and set a new target for further research and development |
Rights: | © Západočeská univerzita v Plzni |
Appears in Collections: | Články / Articles (MLT) Články / Articles (KAE) Applied Electronics 2016 Applied Electronics 2016 |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/35297
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.