Název: Gamma-ray spectroscopy with MAPD array in the readout of LaBr3:Ce scintillator
Autoři: Ahmadov, G.
Ahmadov, F.
Holík, Michael
Berikov, D.
Sadygov, Z.
Akbarov, R.
Nuruyev, S.
Sadigov, A.
Mammadli, A.
Mammadov, R.
Kopatch, Yu.
Přidal, Petr
Yilmaz, E.
Doganci, E.
Zich, Jan
Citace zdrojového dokumentu: AHMADOV, G. AHMADOV, F. HOLÍK, M. BERIKOV, D. SADYGOV, Z. AKBAROV, R. NURUYEV, S. SADIGOV, A. MAMMADLI, A. MAMMADOV, R. KOPATCH, Y. PŘIDAL, P. YILMAZ, E. DOGANCI, E. ZICH, J. Gamma-ray spectroscopy with MAPD array in the readout of LaBr3:Ce scintillator. Journal of Instrumentation, 2021, roč. 16, č. 7, s. 0-12. ISSN: 1748-0221
Datum vydání: 2021
Nakladatel: IOP Publishing
Typ dokumentu: článek
article
URI: 2-s2.0-85111565075
http://hdl.handle.net/11025/46658
ISSN: 1748-0221
Klíčová slova v dalším jazyce: photon detectors for UV;visible and IR photons;scintillators;scintillation and light emission processes;data acquisition circuits;detector control systems
Abstrakt v dalším jazyce: This paper presented a new detector module consisting of a micropixel avalanche photodiode (MAPD-3NM), LaBr3:Ce scintillator, and a compact read-out interface system for detecting gamma-rays in a wide energy range. The MAPD array (4 × 4 channels) was assembled using a singleMAPD-3NMcharacterized by its high photon detection efficiency (∼25%),pixel density (10 000 pixels/mm2), lowoperation voltage (74.5 V), and lowdark current. An active area of a singleMAPD-3NMwas 3.7 × 3.7 mm2, while this value was 17 × 17 mm2 for the assembled array with pixel density of 2190 000. The size of the tested LaBr3:Ce scintillator was 15 × 15 × 15 mm3. According to the characteristics of the detector module, a compact read-out interface device (SPECTRIG MAPD) was developed. SPECTRIG MAPD was designed as a miniature device with low power consumption, which continues to provide a wide spectrum of functions needed for measurement and test silicon photomultipliers (SiPM) and scintillation detectors on their basis. The various experiments were implemented to test the detection performance of a detector module to gamma radiation in the range from 30 keV to 4400 keV.
Práva: Plný text je přístupný v rámci univerzity přihlášeným uživatelům.
© 2021 IOP Publishing Ltd and Sissa Medialab
Vyskytuje se v kolekcích:Články / Articles (KEI)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Holik_2021_JINST_16_P07020.pdf1,25 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/46658

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD