dc.identifier.uri | http://147.228.94.30/images/PDF/Rocnik2011/Cislo5_2011/r5c5c3.pdf | |
dc.identifier.uri | http://hdl.handle.net/11025/653 | |
dc.format | 3 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | Západočeská univerzita v Plzni, Fakulta elektrotechnická | cs |
dc.relation.ispartofseries | Electroscope | cs |
dc.rights | © 2011 Electroscope. All rights reserved. | en |
dc.subject | síťové samozhášecí kabely | cs |
dc.subject | dielektrická měření | cs |
dc.subject | radiační stárnutí | cs |
dc.title | Radiation ageing of flame retardant XLPE Cables | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | The paper discusses the possibilities of using capacitance and tan measurements in the range of very low frequencies for investigation of the influence of radiation on the special LOCA cross-linked polyethylene flame retardant cable dielectric. It was found that the measured and calculated parameters depend significantly on the absorbed dose of radiation. The most probable reason of the structural changes in cross-linked polyethylene exposed to radiation is an additional cross-linking. The results also proved that the capacitance measurements in the very low frequency range could be used in practice for estimation of the absorbed dose in polyethylene cables. | en |
dc.subject.translated | cross-linked flame retardant cables | en |
dc.subject.translated | dielectric measuremets | en |
dc.subject.translated | radiation aging | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Číslo 5 - Diagnostika (2011) Číslo 5 - Diagnostika (2011) |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
r5c5c3.pdf | 187,98 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/653
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.