Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorTomiczek, Petr
dc.date.accessioned2019-11-11T11:00:22Z-
dc.date.available2019-11-11T11:00:22Z-
dc.date.issued2019
dc.identifier.citationJIŘINEC, J., ROT, D. Measuring system for recuperation units. Journal of Nuclear Engineering and Radiation Science, 2019, roč. 5, č. 3, s. 1-5. ISSN 2332-8983.en
dc.identifier.issn2194-1009
dc.identifier.uri2-s2.0-85070820960
dc.identifier.urihttp://hdl.handle.net/11025/35867
dc.format5 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherAmerican Society of Mechanical Engineersen
dc.relation.ispartofseriesJournal of Nuclear Engineering and Radiation Scienceen
dc.rightsPlný text není přístupný.cs
dc.rights© American Society of Mechanical Engineersen
dc.titleDuffing Equation with Nonlinearities Between Eigenvaluesen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessclosedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe article is primarily concerned with the measurement of heat recovery units for different work environments. At present, great emphasis is placed on indoor air quality. The quality of the indoor environment greatly influences the concentration, response, and overall quality of work. This is important in the area of the main control room of the nuclear power plant. For efficient suction of these spaces, it is necessary to handle the entire control process so that the air is delivered to the desired location in proper quantity and quality. For this reason, it is necessary to know the properties of the used components (e.g., recuperator). To calculate the efficiency of heat recovery unit, it is necessary to measure temperature, humidity, and air volume in its individual parts. Based on these requirements, a measurement system was created to achieve the appropriate data for the further optimization process. The first part briefly describes the created measuring system primarily tested on SL-Thermo (Plattling, Germany) units produced by the Sudluft Systemtechnik (Plattling, Germany). The core of the system is based on an industrial programmable logic controller (PLC) in combination with LabVIEW (Austin, TX) software. The software can be used in laboratory condition or in the real operation. The next part is devoted to measurement of the heat recovery unit in laboratory condition, where the different operating states of the heat recovery unit were simulated. On the basis of the measurements made, a final evaluation was made and some structural modifications were recommended, which would increase the efficiency of the regenerative unit.en
dc.subject.translatedSecond order ODEen
dc.subject.translated·Periodic problemen
dc.subject.translatedVariational methoden
dc.subject.translatedCritical pointen
dc.identifier.doi10.1007/978-3-030-26987-6_13
dc.type.statusPeer-revieweden
dc.identifier.obd43927023
dc.project.IDLQ1603/R4S - SUSENcs
dc.project.IDSGS-2018-023/Analýza a vyhodnocení dodávky elektrické energie simulací a modelováním pro dodržení optimálních spolehlivostních a kvalitativních parametrů, s respektováním integrace nových distribuovaných a obnovitelných zdrojů do elektrizační soustavy i odpovídající akumulace, při využití nových, pokročilých metod teoretického a aplikačního výzkumu v elektroenergeticecs
Vyskytuje se v kolekcích:Články / Articles (KEE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Tomiczek2019_Chapter_DuffingEquationWithNonlinearit.pdf219,91 kBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/35867

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD