dc.identifier.citationŠVANTNER, M., ŠTUDENT, J., VESELÝ, Z. Continuous walking-beam furnace 3D zonal model and direct thermal-box barrier based temperature measurement. Case Studies in Thermal Engineering, 2020, roč. 18, č. APR 2020. ISSN 2214-157X.en
dc.identifier.issn2214-157X
dc.identifier.uri2-s2.0-85083807736
dc.identifier.urihttp://hdl.handle.net/11025/37026
dc.description.abstractČlánek popisuje metodu a implementaci 3D zonálního modelu pro výpočet tepelného procesu ohřevu vsázky v průmyslové krokové peci. Je prezentováno přímě měření teplot vsázky při průchodu pecí pomocí tepelné box-bariéry. Jsou porovnány experimentální výsledky s numerickým modelecs
dc.format13 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesCase Studies in Thermal Engineeringen
dc.rights© Elsevieren
dc.subjectměření teplotcs
dc.subjectprůmyslové pececs
dc.subjecttepelná box-bariéracs
dc.subjectzonální modelcs
dc.subjectnumerická simulacecs
dc.subjectkrokové pececs
dc.subjectradiační přenosteplacs
dc.titleContinuous walking-beam furnace 3D zonal model and direct thermal-box barrier based temperature measurementen
dc.title.alternative3D zonální model průběžné krokové pece a přímě měření pomocí tepelné box-bariérycs
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedNumerical simulation of industrial reheating furnaces belongs to important procedures for an optimization of their designand processing parameters. A 3D numerical model of a continuous gas burners heated walking-beam furnace is introduced in this paper. The main benefit of the model is a compromise between its complexity and computing speed. The model connects numerical procedures and empirical knowledge. It is based on a Hottel zonal method and a compartment based solution of heat transfer process in solids. It allows specifying charge, heating system and furnace parameters. The solution includes convective and radiative heat transfer in the furnace including a participation of a semi-transparent gaseous furnace atmosphere. A direct measurement of charge temperature course in a walking-beam furnace using thermocouples and thermal box-barrier are introduced. Comparisons of the measurement results with results of numerical simulations are presented. Connection between direct measurement in the furnace and the numerical simulation parameters is discussed. A good agreement between the theoretical and measured data shows, that the model includes the most important physical process.en
dc.subject.translatedFurnaceen
dc.subject.translatedWalking-beam furnaceen
dc.subject.translatedRadiation heat transferen
dc.subject.translatedNumerical modelen
dc.subject.translatedHottel zonal methoden
dc.subject.translatedThermal box-barrieren
dc.subject.translatedTemperature measurementen
dc.identifier.doi10.1016/j.csite.2020.100608
dc.type.statusPeer-revieweden
dc.identifier.document-number519809800004
dc.identifier.obd43929505
dc.project.IDEF18_069/0010018/LabIR-PAV / Předaplikační výzkum infračervených technologiícs
Vyskytuje se v kolekcích:Články / Articles (CT3)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Svantner_furn zone model - CSTE final.pdf1,23 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/37026

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD