Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorNoorollahi, Younes
dc.contributor.authorGolshanfard, Aminabbas
dc.contributor.authorHashemi Dezaki, Hamed
dc.date.accessioned2022-07-04T10:00:11Z-
dc.date.available2022-07-04T10:00:11Z-
dc.date.issued2022
dc.identifier.citationNOOROLLAHI, Y. GOLSHANFARD, A. HASHEMI DEZAKI, H. A scenario-based approach for optimal operation of energy hub under different schemes and structures. ENERGY, 2022, roč. 251, č. July 2022, s. 1-19. ISSN: 0360-5442cs
dc.identifier.issn0360-5442
dc.identifier.uri2-s2.0-85128148516
dc.identifier.urihttp://hdl.handle.net/11025/49001
dc.format19 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesENERGYen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Elsevieren
dc.titleA scenario-based approach for optimal operation of energy hub under different schemes and structuresen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedBecause of economic and environmental issues' importance in the energy field, moving toward smart energy systems and energy hubs (EHs) has accelerated. The impacts of uncertainties, e.g., stochastic behaviors of renewable distributed generations (DGs), on EHs are fundamental challenges that should be considered carefully. Although several studies have been done in the area of EHs, a knowledge gap exists about developing an approach considering uncertainties under different EHs' structures and topologies. This research purposes of responding to such a research gap. In this research, a scenario-based approach for EHs' optimal operation considering wind turbine (WT) and photovoltaic (PV) uncertainties is proposed. The proposed approach is applied to EH under different schemes. Using the k-means clustering algorithm decreases the computational burden, while the appropriate accuracy is achievable. The proposed stochastic optimization problem is solved using the genetic algorithm (GA). The comparative view is considered to investigate the impacts of cooling and heating components like the heat pump (HP), absorption chiller (AC), and heat storage (HS) on EH's optimal operation and energy cost. According to this research findings, the EH's daily energy cost under a scheme using the AC, HP, and HS is approximately 6.5% less than a scheme only using HP. Also, using the HS and HP alongside the AC leads to 5.6% and 6.4% cost-saving, respectively. But for a better comparison, the investment and operation and maintenance (O&M) cost are considered, in which case Structure 3 (AC þ HP) is more efficient both in terms of energy consumption and investment costs.en
dc.subject.translatedscenario-based approachen
dc.subject.translatedenergy hub schemesen
dc.subject.translatedrenewable energiesen
dc.subject.translatedoptimal operationen
dc.subject.translatedheating and cooling componenten
dc.identifier.doi10.1016/j.energy.2022.123740
dc.type.statusPeer-revieweden
dc.identifier.document-number798562800008
dc.identifier.obd43936022
Vyskytuje se v kolekcích:Články / Articles (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Dezaki_1-s2.0-S0360544222006430-main.pdf4,29 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/49001

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD