Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorRubanenko, Olena
dc.date.accessioned2023-11-06T11:00:26Z-
dc.date.available2023-11-06T11:00:26Z-
dc.date.issued2023
dc.identifier.citationRUBANENKO, O. Energy Consumption Optimisation of Emergency Shelters for Ukrainian War Refugees. Renewable Energy & Power Quality Journal (RE&PQJ), 2023, roč. 21, č. July 2023, s. 451-455. ISSN: 2172-038Xcs
dc.identifier.issn2172-038X
dc.identifier.uri2-s2.0-85163655136
dc.identifier.urihttp://hdl.handle.net/11025/54676
dc.format
dc.format5 s.cs
dc.format.mimetypeapplication/pdf
dc.language.iso
dc.language.isoenen
dc.publisherEuropean Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)en
dc.relation.ispartofseriesRenewable Energy & Power Quality Journal (RE&PQJ)en
dc.rights© European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ)en
dc.titleEnergy Consumption Optimisation of Emergency Shelters for Ukrainian War Refugeesen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe paper deals with optimisation of energy consumption of emergency shelters (tiny houses) for Ukrainian War refugees. Significant amount of Ukrainian citizens lost their homes or were forced to leave their properties. These refugees overcrowd the rest of the country and bring huge problems with accommodation and inclusion into existing communities. Accommodation in schools or gyms is just temporary solution with another unpleasant influence on the society. It is necessary to construct new quarters or communities using cheap but energy very efficient constructions. Several variants of tiny house with various equipment features and living or comfort standard are being discussed and compared. These studies are based on real project realised between Ukrainian non-government organisation Synergy and German development agency weChange. Main goal of this research is consumption optimisation of not particular single shelter but rather of large community of shelters containing hundreds or thousands units called shelter city. The tiny houses itself are designed according to passive solar systems standards and with accent to minimal purchasing costs and operational energy needs. Second important requirement is strong optimisation of shelter’s load chart to significantly decrease influence of the shelter city to power grid connection point. Both tasks are important because the Russian attack against Ukraine brings new tasks for power engineering sector. Electricity production, transmission, distribution and consumption must face new challenges. Nowadays more than 35 % of critical infrastructure is being damaged. Remaining infrastructure would be more overloaded, if new customers are connected without energy needs optimisation.en
dc.subject.translatedinfluence on griden
dc.subject.translatedload chart optimisationen
dc.subject.translatedshelter cityen
dc.subject.translatedtiny houseen
dc.identifier.doi10.24084/repqj21.352
dc.type.statusPeer-revieweden
dc.identifier.obd43940556
Vyskytuje se v kolekcích:Články / Articles (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
352-23-rubanenko.pdf1,85 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/54676

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD