Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorMichniakova, Mária
dc.contributor.authorJanoušek, Ladislav
dc.contributor.authorSmetana, Milan
dc.contributor.editorKropík, Petr
dc.date.accessioned2017-04-07T09:32:17Z
dc.date.available2017-04-07T09:32:17Z
dc.date.issued2011
dc.identifier.citationAMTEE ’11 : tenth international conference on Advanced Methods in the Theory of Electrical Engineering : September 06-09, 2011 [Cheb, Czech Republic], p. VIII-7-8.en
dc.identifier.isbn978-80-7043-993-7
dc.identifier.urihttp://cpee.zcu.cz/AMTEE/ArchivedProceedings.aspx
dc.identifier.urihttp://hdl.handle.net/11025/25936
dc.format2 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUniversity of West Bohemiaen
dc.rights© University of West Bohemiaen
dc.subjectnedestruktivní hodnocenícs
dc.subjectpulzované vířivé proudycs
dc.subjectsignál odezvycs
dc.subjecthloubka vadycs
dc.subjectrozlišenícs
dc.titleImpact of probe configuration on cracks’ resolution in pulsed eddy current non-destructive evaluationen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedPulsed eddy current non-destructive evaluation is concerned in the paper. Impact of eddy-current probe’s configuration on response signals, especially on crack’s depth resolution from the signals is numerically investigated. Orientation of an exciting coil of the probe regarding surface of a tested material is changed while the coil’s dimensions are varied at the same time to evaluate influence of the parameters on induction coupling between the probe and the material. The induction coupling affects information transfer between the probe and the material and consequently it influences the resolution of detected defects. Numerical simulations with various diameters of the coil are then performed and evaluated to investigate impact of this parameter on resolution of defects with different depths.en
dc.subject.translatednon-destructive evaluationen
dc.subject.translatedpulsed eddy currentsen
dc.subject.translatedresponse signalen
dc.subject.translateddepth of defecten
dc.subject.translatedresolutionen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:CPEE – AMTEE 2011

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
Michniakova.pdfPlný text42,19 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/25936

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.