Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorSon, Jinwon
dc.contributor.authorChoi, Young
dc.contributor.editorSkala, Václav
dc.date.accessioned2017-11-08T10:30:09Z
dc.date.available2017-11-08T10:30:09Z
dc.date.issued2014
dc.identifier.citationWSCG 2014: communication papers proceedings: 22nd International Conference in Central Europeon Computer Graphics, Visualization and Computer Visionin co-operation with EUROGRAPHICS Association, p. 293-298.en
dc.identifier.isbn978-80-86943-71-8
dc.identifier.uriwscg.zcu.cz/WSCG2014/!!_2014-WSCG-Communication.pdf
dc.identifier.urihttp://hdl.handle.net/11025/26426
dc.format6 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherVáclav Skala - UNION Agencycs
dc.relation.ispartofseriesWSCG 2014: communication papers proceedingsen
dc.rights@ Václav Skala - UNION Agencycs
dc.subjectmodelování krevních cévcs
dc.subjectCTcs
dc.subjectIVUScs
dc.subjectrentgenový angiogramcs
dc.titleThree-dimensional blood vessel modeling method considering IVUS catheter insertionen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedIn this paper, we propose a new 3D (three-dimensional) blood vessel modeling method for FSI (fluid-structure interaction) analysis. Because of the nature of medical images, a 3D blood vessel model that includes intima and adventitia cannot be reconstructed using a single medical image. Many researchers have used IVUS (intravascular ultrasound) images to obtain detailed intima and adventitia information and X-ray angiogram images to calculate the position and orientation of IVUS images. By combining these types of medical images, 3D blood vessel model can be generated. However, when an IVUS image is taken, a catheter attached to a miniaturized ultrasound device is inserted into the blood vessel, so the shape of the blood vessel is deformed. The resulting 3D blood vessel model developed by combining the IVUS and X-ray angiogram images reflects the deformation of the blood vessel by the IVUS catheter. To solve this problem, we propose a novel method for 3D blood vessel modeling using undeformed intima and adventitia information obtained with an IVUS catheter.en
dc.subject.translatedblood vessel modelingen
dc.subject.translatedCTen
dc.subject.translatedIVUSen
dc.subject.translatedX-ray angiogramen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:WSCG 2014: Communication Papers Proceedings

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
Son.pdfPlný text475,73 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/26426

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.