Title: | On/off cycling test of low-temperature PEM fuel cell at fully humidified conditions |
Other Titles: | Testování nízkoteplotního palivového článku typu PEM s plně zvlhčenými pracovními plyny |
Authors: | Novotný, Pavel Tomáš, Martin Němec, Tomáš Kullová, Lucie Maršík, František |
Citation: | NOVOTNÝ, P., TOMÁŠ, M., NĚMEC, T., KULLOVÁ, L., MARŠÍK, F. On/off cycling test of low-temperature PEM fuel cell at fully humidified conditions. International Journal of Green Energy, 2019, ro�. 16, �. 14, s. 1189-1195. ISSN 1543-5075. |
Issue Date: | 2019 |
Publisher: | Taylor & Francis |
Document type: | článek article |
URI: | 2-s2.0-85073567115 http://hdl.handle.net/11025/36316 |
ISSN: | 1543-5075 |
Keywords: | Akcelerované testování;Palivový článek PEM;elektrochemická impedanční spektroskopie;ekvivalentní okruh;uvolnění fluoridů;polarizační křivka |
Keywords in different language: | Accelerated testing;PEM fuel cell;electrochemical impedance spectroscopy;equivalent circuit;release fluorides;polarization curve |
Abstract: | Akcelerované testování patří mezi nejrozšířenější způsob testování výkonu a degradace sestavy membrán a elektrod (MEA) v oblasti vodíkových palivových článků s polymerní membránou (PEMFC). K testování byly využity standardizované protokoly (JRC) a zkoumány byly dvě MEA od výrobců Paxitech a ElectroChem. Výkonové křivky byly změřeny před a po testování. Elektrické vlastnosti byly zkoumány elektrochemickou impedanční spektroskopií (EIS). K vyhodnocení dat z EIS bylo využito ekvivalentních okruhů složených z rezistoru a Voigtovy struktury v sérii s CPE (constant phase element). Voda z anodické i katodické strany palivového článku byla zachycena a dále analyzována. Produkovaná voda byla využita k určení obsahu uvolněných fluoridů, a tím byla stanovena míra degradace MEA. |
Abstract in different language: | Accelerated stress testing is one of the most used approaches to characterize the performance and the degradation of the membrane electrode assembly (MEA) in low-temperature hydrogen polymer electrolyte membrane fuel cells (PEMFC). A standard JRC on/off testing procedure was used to characterize two sets of commercial MEAs, by ElectroChem and by PaxiTech, respectively. Performance characteristics prior to and after the on/off procedure were measured. Thechanges in the resistivity of the MEA were examined by electrochemical impedance spectroscopy (EIS). The EIS data were analyzed and interpreted by a suitable equivalent circuit that consisted of a resistor and the Voigt’s structure in series with constant phase elements. Water on the anode side and the cathode side of the PEMFC was collected during the on/off procedure. The fluoride emission rate was determined from the collected water to obtain information about the chemical degradation of the MEA samples. |
Rights: | Plný text není přístupný. © Taylor & Francis |
Appears in Collections: | Články / Articles (CT2) OBD |
Files in This Item:
File | Size | Format | |
---|---|---|---|
Novotny_On_off_cycling.pdf | 1,4 MB | Adobe PDF | View/Open Request a copy |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/36316
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.