Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Burian, Petr | |
dc.contributor.author | Broulím, Pavel | |
dc.contributor.author | Bergmann, Benedikt, Ludwig | |
dc.contributor.author | Tlustos, Lukáš | |
dc.date.accessioned | 2020-08-31T10:00:21Z | - |
dc.date.available | 2020-08-31T10:00:21Z | - |
dc.date.issued | 2020 | |
dc.identifier.citation | BURIAN, P., BROULÍM, P., BERGMANN, B. L., TLUSTOS, L. Ethernet embedded readout interface for Timepix2 – Katherine readout for Timepix2. Journal of Instrumentation, 2020, roč. 15, č. 1, s. 0-15. ISSN 1748-0221. | en |
dc.identifier.issn | 1748-0221 | |
dc.identifier.uri | 2-s2.0-85081681606 | |
dc.identifier.uri | http://hdl.handle.net/11025/39538 | |
dc.format | 16 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | IOP Publishing | en |
dc.relation.ispartofseries | Journal of Instrumentation | en |
dc.rights | Plný text je přístupný v rámci univerzity přihlášeným uživatelům. | cs |
dc.rights | © IOP Publishing | en |
dc.title | Ethernet embedded readout interface for Timepix2 – Katherine readout for Timepix2 | en |
dc.type | článek | cs |
dc.type | article | en |
dc.rights.access | restrictedAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | This paper introduces a readout system for the Timepix2. Firstly, this chip is described and the readout modes are discussed in detail. The new readout system presented is based on the Gigabit Ethernet interface and implements pre-processing, i.e. decoding of the raw pixel data, directly in the hardware. The device suppresses zero pixels, so that only useful data are sent to the computer/server. In a special independent mode, the readout can send completed data files to a remote server via SSH and does not need to use a control software. In island mode, the device stores measured data to a local storage (SD card). The process of calibration and its results are also discussed. An energy resolution of approximately 1.5 keVwas achieved for 60 keVgamma-rays from an 241Am source. We present enhanced features of the readout system facilitating measurements and data evaluation, such as the HW support of clustering and Matrix Occupation Control. The former implements the pixel clustering directly in the hardware and sends energy calibrated results of the cluster finding algorithm to the computer. The latter automatically controls acquisition time of detector in order to reduce cluster overlapping. Measurements with Timepix2 are presented in iron and electron test beams. Results show that pixels of Timepix2 saturate at a per-pixel energy deposition of 1.9 MeV. | en |
dc.subject.translated | detector control systems | en |
dc.subject.translated | detector and experiment monitoring and slow-control systems | en |
dc.subject.translated | architecture | en |
dc.subject.translated | hardware | en |
dc.subject.translated | algorithms | en |
dc.subject.translated | databases | en |
dc.subject.translated | data acquisition circuits | en |
dc.subject.translated | data acquisition concepts | en |
dc.subject.translated | particle tracking detectors | en |
dc.identifier.doi | 10.1088/1748-0221/15/01/C01037 | |
dc.type.status | Peer-reviewed | en |
dc.identifier.document-number | 525449100037 | |
dc.identifier.obd | 43929529 | |
dc.project.ID | LO1607/RICE-NETESIS - nové technologie a koncepce pro inteligentní průmyslové systémy (NETESIS) | cs |
dc.project.ID | EF16_019/0000766/Inženýrské aplikace fyziky mikrosvěta | cs |
Vyskytuje se v kolekcích: | Články / Articles (RICE) Články / Articles (KAE) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
Burian_2020_J._Inst._15_C01037.pdf | 4,16 MB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/39538