Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorGundebommu, Sree Lakshmi
dc.contributor.authorRubanenko, Oleksandr
dc.contributor.authorRubanenko, Olena
dc.contributor.authorHunko, Iryna
dc.date.accessioned2021-01-18T11:00:22Z-
dc.date.available2021-01-18T11:00:22Z-
dc.date.issued2020
dc.identifier.citationGUNDEBOMMU, S.L., RUBANENKO, O., RUBANENKO, O., HUNKO, I. Research processes of oil and paper insulation of high-voltage equipment during operation. In: 2019 International Conference on Multifunctional Materials (ICMM 2019) : /proceedings/. Marylend: American Institute of Physics Inc., 2020. s. 030021-1 - 030021-7. ISBN 978-0-7354-2032-8 , ISSN 0094-243X.cs
dc.identifier.isbn978-0-7354-2032-8
dc.identifier.issn0094-243X
dc.identifier.uri2-s2.0-85094568527
dc.identifier.urihttp://hdl.handle.net/11025/42494
dc.format7 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherAmerican Institute of Physics Inc.en
dc.relation.ispartofseries2019 International Conference on Multifunctional Materials (ICMM 2019) : /proceedings/en
dc.rights© American Institute of Physicsen
dc.titleResearch processes of oil and paper insulation of high-voltage equipment during operationen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe article analyzes the factors that accelerate the aging process of the oil-paper insulation of the condenser type and shorten its service life. Attention is drawn to the fact that the breakdown of flat insulation made of condenser paper occurs at the location of the inclusion, which approximately corresponds to the field of uniform field. An example of damage to the insulation of a current transformer due to its aging and moisture is given. This work was analysed the influence of thickness and density of paper, grade of mineral oil on short-term electrical strength. The characteristics of the insulating papers of the permeable composition largely determine the electrical strength of the paper-oil insulation.Since paper-oil insulation consists of a series of successive layers of paper and oil, it is advisable to present such insulation by the equivalent scheme shown in fig. 1, in which the thickness of the paper-oil dielectric is divided into two layers: paper (fiber) and mineral oil, connected in series.en
dc.subject.translatedinsulating oilen
dc.subject.translatedpower transformersen
dc.subject.translatedbushingsen
dc.identifier.doi10.1063/5.0019834
dc.type.statusPeer-revieweden
dc.identifier.obd43931445
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Rubanenko_5.0019834-1-2.pdf910,3 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/42494

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD