Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorNovák, Viktor
dc.contributor.authorVolf, Jaromír
dc.contributor.authorNovák, Daniel
dc.contributor.authorVrbík, Václav
dc.contributor.authorRyženko, Vladimír
dc.contributor.authorStebila, Ján
dc.date.accessioned2023-01-30T11:00:26Z-
dc.date.available2023-01-30T11:00:26Z-
dc.date.issued2022
dc.identifier.citationNOVÁK, V. VOLF, J. NOVÁK, D. VRBÍK, V. RYŽENKO, V. STEBILA, J. Evaluation of Electrical Resistance of Electrodes with Conductive Ink for Agriculture Application Using Computer Technology. Research in Agricultural Engineering, 2022, roč. 68, č. 4, s. 194-200. ISSN: 1212-9151cs
dc.identifier.issn1212-9151
dc.identifier.uri2-s2.0-85144424582
dc.identifier.urihttp://hdl.handle.net/11025/51150
dc.format7 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherCzech Academy of Agricultural Sciencesen
dc.relation.ispartofseriesResearch in Agricultural Engineeringen
dc.rights© Czech Academy of Agricultural Sciencesen
dc.titleEvaluation of Electrical Resistance of Electrodes with Conductive Ink for Agriculture Application Using Computer Technologyen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe article presents the ongoing research, which aims to select suitable electrodes and mixtures of conductive inks, which will be used as a converter between pressure and electrical quantities in the design of planar pressure transducers. In the described research, we continue in our previous work and in the work of other authors who have previously dealt with the properties of conductive inks and electrodes. Due to the only partial results in the given field, we decided to perform an extensive and original measurement of total 172 combinations of different electrode sizes, various conductive ink mixtures and ink layer thicknesses. Thanks to this, it will be possible in the future to select a suitable combination of electrodes and inks when designing pressure sensors for industrial and agricultural applications without the need to perform time-consuming preparatory measurements. The aim of the measurement is also to determine the usable working range of pressures and the corresponding sensitivity for certain combinations of electrodes and inks, and also to exclude those variants which are unsuitable for the given purposes. This paper presents the introductory part of the measurement, which aims to verify the methodology of the measurement on a test plate at robotized workspace, that is connected in real time with PC via the program LabView. The described introductory measurement proved our methodology to be suitable to the given purpose; however, there emerged minor problems concerning the actual working pressure range of the transducer and consequential necessary adjustments of the control program.en
dc.subject.translatedconductive inken
dc.subject.translatedelectrodeen
dc.subject.translatedLabViewen
dc.subject.translatedpressureen
dc.subject.translatedtactile sensoren
dc.subject.translatedtyreen
dc.identifier.doi10.17221/60/2021-RAE
dc.type.statusPeer-revieweden
dc.identifier.obd43934184
Vyskytuje se v kolekcích:Články / Articles (KVD)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
www_rae-202204-0004.pdf1,35 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/51150

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD