Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorOghabian, M. A.
dc.contributor.authorMohammadi, F. I.
dc.contributor.authorSarkar, S.
dc.contributor.authorKarimian, A. R.
dc.contributor.editorSkala, Václav
dc.date.accessioned2013-01-25T08:33:04Z-
dc.date.available2013-01-25T08:33:04Z-
dc.date.issued2004
dc.identifier.citationWSCG '2004: Posters: The 12-th International Conference in Central Europe on Computer Graphics, Visualization and Computer Vision, 2.-6. February 2004, Plzen, p. 205-208.en
dc.identifier.isbn80-903100-6-0
dc.identifier.urihttp://wscg.zcu.cz/wscg2004/Papers_2004_Poster/D53.pdf
dc.identifier.urihttp://hdl.handle.net/11025/953
dc.description.abstractIn Single Photon Emission Computed Tomography (SPECT), the data acquisition occurs over a relatively long time, typically in the range of 5-30 minutes. During this period, the patient must lie still to guarantee the image quality. Nevertheless, patient movement has frequently been reported in clinical applications. This movement causes misalignment of the projection frames, which degrades the reconstructed image and may introduce artifacts. However, the ability to detect and correct for the motion using a computational method is valuable for quality assurance of SPECT imaging. In this work a correlation function based on Linogram and Sinogram of the projection is evaluated in order to estimate the occurred motion and correct it for the best alignment. By our implemented method the motion artifacts of our cases reduced considerably and our results showed that the misalignment (motion) between the projections could be found with a small error depending on the resolution of the images (pixel size), and the time and duration of the applied motion during the course of projection acquisition.en
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUNION Agencyen
dc.relation.ispartofseriesWSCG '2004: Postersen
dc.rights© UNION Agencycs
dc.subjectpočítačová tomografiecs
dc.subjectpohyb pacientacs
dc.subjectkorekce pohybucs
dc.subjectkorelační funkcecs
dc.titleMotion correction of SPEC projection before reconstructionen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.subject.translatedsingle photon emission computed tomographyen
dc.subject.translatedpatient motionen
dc.subject.translatedmotion correctionen
dc.subject.translatedcorrelation functionen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:WSCG '2004: Posters

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
D53.pdf372,27 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/953

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.