Title: Selection of Ideal Operating Point for Infrared Camera System
Authors: Čech, Jiří
Rozkovec, Martin
Citation: 2018 International Conference on Applied Electronics: Pilsen, 11th – 12th September 2018, Czech Republic, p. 19-22.
Issue Date: 2018
Publisher: Západočeská univerzita v Plzni
Document type: konferenční příspěvek
conferenceObject
URI: http://hdl.handle.net/11025/35462
ISBN: 978–80–261–0721–7
ISSN: 1803–7232
Keywords: infračervená kamera;infračervené záření dlouhé vlnové délky;teplotní rozdíl ekvivalentní šumu;nechlazené bolometry FPA
Keywords in different language: infrared camera;long wave infrared range;noise equivalent temperature difference;uncooled bolometers FPA
Abstract in different language: The paper presents identification of temperature range and gain parameters of long wave infrared camera. Various characteristics of tunable parameters of micro bolometer focal plane array were acquired and the optimal operating point was accordingly selected. The camera temperature characteristic and noise-equivalent temperature difference was measured for selected operating point. Results will be used in a project called robust detection system, where there are special requirements to be met.
Rights: © Západočeská univerzita v Plzni
Appears in Collections:Applied Electronics 2018
Applied Electronics 2018

Files in This Item:
File Description SizeFormat 
Čech.pdfPlný text738,55 kBAdobe PDFView/Open


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/35462