Title: | Safety Integrity Evaluation of Safety Function |
Authors: | Ždánský, Peter Balák, Jozef Rástočný, Karol |
Citation: | 2018 International Conference on Applied Electronics: Pilsen, 11th – 12th September 2018, Czech Republic, 183-188. |
Issue Date: | 2018 |
Publisher: | Západočeská univerzita v Plzni |
Document type: | konferenční příspěvek conferenceObject |
URI: | http://hdl.handle.net/11025/35498 |
ISBN: | 978–80–261–0721–7 |
ISSN: | 1803–7232 |
Keywords: | bezpečnostní funkce bezpečnostní integrita bezpečnostní systém sPLC IEC 61 508 Markovův řetězec validace |
Keywords in different language: | safety function safety integrity safety related system sPLC IEC 61 508 Markov Chain validation |
Abstract in different language: | For a possibility of using the safety relevant system in practice, it is necessary to prove, that safety requirements, which are defined based on results of risk analysis, are fulfilled. Part of proving the safety of safety relevant system is also quantitative evaluation of safety integrity of the hardware which is involved in the safety functions realization. Objective of the paper is to compare different ways of the quantitative hardware safety integrity evaluation. For a specific technological process are identified hazards, their consequences and from them resulting safety functions. For each defined safety function is, by three different procedures, calculated the probability of dangerous failure per hour. At the end of the paper are stated reasons of results mismatch, which were obtained using different approaches. |
Rights: | © Západočeská univerzita v Plzni |
Appears in Collections: | Applied Electronics 2018 Applied Electronics 2018 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Ždánsky2.pdf | Plný text | 898,35 kB | Adobe PDF | View/Open |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/35498
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.