Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorJonášová, Alena
dc.contributor.authorVimmr, Jan
dc.date.accessioned2021-06-14T14:21:55Z-
dc.date.available2021-06-14T14:21:55Z-
dc.date.issued2021
dc.identifier.citationJONÁŠOVÁ, A., VIMMR, J. On the relevance of boundary conditions and viscosity models in blood flow simulations in patient‐specific aorto‐coronary bypass models. International Journal for Numerical Methods in Biomedical Engineering, 2021, roč. 37, č. 4. ISSN 2040-7939.cs
dc.identifier.issn2040-7939
dc.identifier.uri2-s2.0-85100234064
dc.identifier.urihttp://hdl.handle.net/11025/43643
dc.description.abstractSnahou všech numerických simulací proudění krve je aplikovat fyziologicky korektní okrajové podmínky. Ne jinak tomu je i v případě modelování hemodynamiky v aorto-koronárních bypassech, kde vlastnosti koronárního oběhu mohou výraznou měrou ovlivnit relevantnost získaných výsledků. V tomto ohledu se předložená práce zaměřuje na dva charakteristické rysy koronárního oběhu – fázický průtok krve a hemoreologii. Obě tyto vlastnosti jsou modelovány na příkladě tří reálných geometrií bypassů. Pro studium fázického charakteru toku krve v koronárních artériích je zvolen víceškálový přístup v kombinaci s pěti různými typy okrajových podmínek (střední arteriální tlak, Windkessel model a tři typově odlišné 0D modely). Na základě numerických výsledků je vybrán nejvhodnější typ okrajové podmínky, který je následně užit pro analýzu nenewtonského chování krve v koronárním oběhu. Ve snaze stanovit vliv modelů viskozity na podobu proudového pole a rozložení smykového napětí na stěně bypassů, jsou pro potřeby této práce aplikovány dva nenewtonské modely popisující krev jako pseudoplastickou kapalinu. Z provedené analýzy získaných výsledků jsou patrné výborné vlastnosti 0D modelů v přímém kontrastu k variantám s konstantním výstupním tlakem, které mají sklon výrazně nadhodnocovat hodnoty všech sledovaných veličin. Co se týče tokových vlastností krve v koronárním řečišti, byl provedenými simulacemi potvrzen význam geometrie jako klíčového faktoru při modelování nenewtonských efektů této kapaliny.cs
dc.format30 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherWileyen
dc.relation.ispartofseriesInternational Journal for Numerical Methods in Biomedical Engineeringen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Wileyen
dc.subjectkoronární oběhcs
dc.subject0D modelcs
dc.subjectvíceškálový přístupcs
dc.subjectreálná geometriecs
dc.subjectpseudoplastická kapalinacs
dc.subjectWindkessel modelcs
dc.titleOn the relevance of boundary conditions and viscosity models in blood flow simulations in patient‐specific aorto‐coronary bypass modelsen
dc.title.alternativeVýznam okrajových podmínek a modelů viskozity v numerických simulacích proudění krve v reálných modelech aorto-koronárního bypassucs
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedPhysiologically realistic results are the aim of every blood flowsimulation. This is not different in aorto‐coronary bypasses where the properties of the coronary circulation may significantly affect the relevance of the performed simulations. By considering three patient‐specific bypass geometries, the present paper focuses on two aspects of the coronary blood flow—its phasic flow pattern and its behaviour affected by blood rheology. For the phasic flow property, a multiscale modelling approach is chosen as a means to assess the ability of five different types of coronary boundary conditions (mean arterial pressure, Windkessel model and three lumped parameter models) to attain realistic coronary hemodynamics. From the analysed variants of boundary conditions, the best option in terms of physiological characteristics and its potential for use in patient‐based simulations, is utilised to account for the effect of shear‐dependent viscosity on the resulting hemodynamics and wall shear stress stimulation. Aside from the Newtonian model, the blood rheology is approximated by two non‐Newtonian models in order to determine whether the choice of a viscosity model is important in simulations involving coronary circulation. A comprehensive analysis of obtained results demonstrated notable superiority of all lumped parameter models, especially in comparison to the constant outlet pressure, which regardless of bypass type gave overestimated and physiologically misleading results. In terms of rheology, it was noted that blood in undamaged coronary arteries behaves as a Newtonian fluid, whereas in vessels with atypical lumen geometry, such as that of anastomosis or stenosis, its shear‐thinning behaviour should not be ignored.en
dc.subject.translatedcoronary circulationen
dc.subject.translatedlumped parameter modelen
dc.subject.translatedmultiscale approachen
dc.subject.translatedpatient-specific geometryen
dc.subject.translatedshear-thinning non-Newtonian fluiden
dc.subject.translatedWindkessel modelen
dc.identifier.doi10.1002/cnm.3439
dc.type.statusPeer-revieweden
dc.identifier.document-number613994300001
dc.identifier.obd43931787
dc.project.IDEF17_048/0007280/Aplikace moderních technologií v medicíně a průmyslucs
Vyskytuje se v kolekcích:Články / Articles (KME)
Články / Articles (NTIS)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
J-Num-Biomed-Eng_2021__cnm.3439.pdf9,14 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/43643

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.