Title: Impact of 2oo3 Architecture Recovery on the Safety Integrity of a Safety Function
Authors: Rástočný, Karel
Ždánsky, Juraj
Medvedík, Milan
Citation: 2021 International Conference on Applied Electronics: Pilsen, 7th – 8th September 2021, Czech Republic, p. 137-140.
Issue Date: 2021
Publisher: University of West Bohemia
Document type: conferenceObject
konferenční příspěvek
URI: http://hdl.handle.net/11025/45582
ISBN: 978–80–261–0972–3 (Print)
978–80–261–0973–0 (Online)
ISSN: 1803–7232 (Print)
1805–9597 (Online)
Keywords: zotavení;bezpečnost;bezpečnostní funkce;SIL;SRES
Keywords in different language: recovery;safety;safety function;SIL;SRES
Abstract in different language: One of the basic features of a safety function is the safety integrity level. This feature also affects the technical solution of the system that implements the safety function. One of the parameters that affect the safety integrity of a safety-relevant system is its recovery to the original state after a failure has occurred. The method of recovery a safety-relevant system after the occurrence of a failure to its original state depends not only on its technical solution, but also on the method of its operation. The paper deals with the influence of various methods of recovery on the safety integrity of the safety function, which is implemented by an electronic safety-relevant system with a 2oo3 architecture.
Rights: © University of West Bohemia, 2021
Appears in Collections:Applied Electronics 2021
Applied Electronics 2021

Files in This Item:
File Description SizeFormat 
Impact_of_2oo3_Architecture_Recovery_on_the_Safety_Integrity_of_a_Safety_Function.pdfPlný text630,46 kBAdobe PDFView/Open


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/45582

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.