Title: Geometrické reprezentace svalových vláken a jejich vliv na ramena momentů sil
Other Titles: Geometric Representations of the Muscle Fibres and their Impact on the Moments Arms
Authors: Rypl, Lukáš
Advisor: Kohout Josef, Doc. Ing. Ph.D.
Referee: Majdišová Zuzana, Ing. Bc. Ph.D.
Issue Date: 2021
Publisher: Západočeská univerzita v Plzni
Document type: bakalářská práce
URI: http://hdl.handle.net/11025/44228
Keywords: muskuloskeletální modelování;catmull-rom křivky;signed distance field;detekce kolizí
Keywords in different language: musculoskeletal modelling;catmull-rom curve;signed distance field;collision detection
Abstract: Práce se zabývá reprezentací svalových vláken prostřednictvím Catmull-Rom křivek od jejich tvorby až po deformaci (simulaci pohybu). Počet segmentů, ze kterých se vlákno skládá, je určen automaticky pomocí adaptivní metody navržené v práci. Zvýšený počet segmentů zajistí lepší reprezentaci vlákna. Pro úpravu vláken za běhu byla zavedena metoda pro detekci kolize povrchového modelu kosti a řídícího bodu vlákna, postavená na implementaci signed distance field v knihovně Discregrid. Body vlákna nacházející se uvnitř kosti byly díky tomu přesunuty na její povrch. V porovnání se současným přístupem je navržené řešení výrazně přesnější, přestože negarantuje, že jednotlivé segmenty vlákna nebudou kolidovat, neboť dochází k případům, kdy body jsou mimo kost, ale jejich spojnice kostí prochází.
Abstract in different language: The thesis deals with the representation of muscle fibers through Catmull-Rom curves from their formation to deformation (motion simulation). The number of segments that make up a fiber is determined automatically using the adaptive method proposed in the work. The increased number of segments ensures a better representation of the fiber. To modify the fibers at runtime, a method for detecting the collision of the bone surface model and the fiber control point was introduced, based on the implementation of a signed distance field in the Discregrid library. The points of fiber located inside the bone were thus moved to its surface. Compared to the current approach, the proposed solution is significantly more accurate, although it does not guarantee that the individual fiber segments will not collide, as there are cases where the points are outside the bone, but line between them passes through the bone.
Rights: Plný text práce je přístupný bez omezení.
Appears in Collections:Bakalářské práce / Bachelor´s works (KIV)

Files in This Item:
File Description SizeFormat 
Bakalarska prace - Lukas Rypl A18B0304P.pdfPlný text práce12,25 MBAdobe PDFView/Open
A18B0304P_Posudek.pdfPosudek oponenta práce621,57 kBAdobe PDFView/Open
A18B0304P_Hodnoceni.pdfPosudek vedoucího práce230,66 kBAdobe PDFView/Open
A18B0304P_Obhajoba.pdfPrůběh obhajoby práce105,59 kBAdobe PDFView/Open


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/44228

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.